Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 41
Filtrar
1.
Aesthetic Plast Surg ; 47(5): 1751-1758, 2023 10.
Artigo em Inglês | MEDLINE | ID: mdl-37337054

RESUMO

INTRODUCTION: Measuring breast volume is important to obtain satisfactory breast surgery results, and many techniques are used for this purpose. Thus, the aim of the present study was to compare 3 breast volume techniques: Pessoa's single marking technique, magnetic resonance imaging (MRI) and Crisalix 3D software®. METHODS: Fourteen patients indicated for mammoplasty were selected. Three breast volume measurement techniques were compared: Pessoa's single marking technique, MRI and Crisalix 3D software®. The volumes were tabulated and analyzed using R software. RESULTS: Average age was 30.93 ± 10.25 years. The breast volume was 1554.54 ± 512.54 cm3, as measured by the MRI technique (considered the gold standard), 1199.64 ± 403.13 cm3 using Crisalix 3D software® and 1518.04 ± 468.72 cm3 by Pessoa's single marking technique. Comparison between the Crisalix 3D software® and MRI techniques using the pairwise t test demonstrated a statistically significant difference (t = 4.3957, df = 27, p value = 0001543), but no significant difference between the single marking and MRI techniques (t = 1.3841, df = 27, p value = 0.1777). CONCLUSION: When compared to MRI, breast volume measurement using Pessoa's single marking technique showed no statistically significant difference between them. However, the Crisalix 3D® technique exhibited a difference in relation to MRI. Anthropometric measurements are useful in measuring breast volume because they are easy to obtain, practical and inexpensive, and should be part of a plastic surgeon's arsenal. LEVEL OF EVIDENCE IV: This journal requires that authors assign a level of evidence to each article. For a full description of these evidence-based medicine ratings, please refer to the Table of Contents or the online Instructions to Authors www.springer.com/00266 .


Assuntos
Imageamento Tridimensional , Mamoplastia , Humanos , Adulto Jovem , Adulto , Mama/diagnóstico por imagem , Mama/cirurgia , Mamoplastia/métodos , Software , Imageamento por Ressonância Magnética/métodos , Resultado do Tratamento , Estética , Estudos Retrospectivos
2.
Rev Bras Ortop (Sao Paulo) ; 58(1): 114-120, 2023 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-36969786

RESUMO

Objectives To better characterize the role of endoscopic cubital tunnel release in leprosy neuritis and determine whether there is an improvement in pain, sensitivity, and strength with the use of this minimally invasive technique. Methods A total of 44 endoscopic procedures for ulnar nerve decompression at the elbow were performed in patients who were previously diagnosed with leprosy neuritis. The inclusion criteria were surgical indication for ulnar nerve release and clinical treatment failure for 4 weeks in patients with cubital tunnel syndrome who had their ulnar nerve function, whether motor or sensitive, deteriorated progressively despite the treatment with prednisone 1 mg/kg/day and physiotherapy. For endoscopic release, the CTS Relief Kit (Linvatec. Largo, FL, USA) and a standard 4mm 30° arthroscope were used. Results The study included 39 patients, 29 (74.4%) males and 10 (25.6%) females. The age of the patients ranged from 12 to 64 years (33 ± 14.97). Five patients underwent bilateral release. The release demonstrated a statistically significant improvement in pain ( p 0.002), in sensitivity ( p < 0.001), and in strength ( p < 0.001). The best results were obtained when ulnar release was performed less than 6 months after surgery indication. None of the procedures were converted from endoscopic to open. No major complications (infection, vascular injury, and nervous injury) were reported. One patient had ulnar nerve subluxation. Conclusion The endoscopic release of the ulnar nerve at the elbow in leprosy neuritis entails true and safe benefits for the patient, such as improvement in pain, sensitivity and strength.

3.
Rev. bras. ortop ; 58(1): 114-120, Jan.-Feb. 2023. tab, graf
Artigo em Inglês | LILACS | ID: biblio-1441346

RESUMO

Abstract Objectives To better characterize the role of endoscopic cubital tunnel release in leprosy neuritis and determine whether there is an improvement in pain, sensitivity, and strength with the use of this minimally invasive technique. Methods A total of 44 endoscopic procedures for ulnar nerve decompression at the elbow were performed in patients who were previously diagnosed with leprosy neuritis. The inclusion criteria were surgical indication for ulnar nerve release and clinical treatment failure for 4 weeks in patients with cubital tunnel syndrome who had their ulnar nerve function, whether motor or sensitive, deteriorated progressively despite the treatment with prednisone 1 mg/kg/day and physiotherapy. For endoscopic release, the CTS Relief Kit (Linvatec. Largo, FL, USA) and a standard 4mm 30° arthroscope were used. Results The study included 39 patients, 29 (74.4%) males and 10 (25.6%) females. The age of the patients ranged from 12 to 64 years (33 ± 14.97). Five patients underwent bilateral release. The release demonstrated a statistically significant improvement in pain (p 0.002), in sensitivity (p< 0.001), and in strength (p< 0.001). The best results were obtained when ulnar release was performed less than 6 months after surgery indication. None of the procedures were converted from endoscopic to open. No major complications (infection, vascular injury, and nervous injury) were reported. One patient had ulnar nerve subluxation. Conclusion The endoscopic release of the ulnar nerve at the elbow in leprosy neuritis entails true and safe benefits for the patient, such as improvement in pain, sensitivity and strength.


Resumo Objetivos Os objetivos deste estudo foram caracterizar melhor o papel da liberação endoscópica do túnel cubital na neurite hansênica e determinar se há melhora da dor, sensibilidade e força com esta técnica minimamente invasiva. Métodos Um total de 44 procedimentos endoscópicos para descompressão do nervo ulnar no cotovelo foram realizados em pacientes previamente diagnosticados com neurite por hanseníase. Os critérios de inclusão foram indicação cirúrgica para liberação do nervo ulnar e insucesso do tratamento clínico por 4 semanas em pacientes com síndrome do túnel cubital que sofreram deterioração progressiva da função motora ou sensitiva do nervo ulnar apesar do tratamento de 1 mg/kg/dia de prednisona e fisioterapia. A liberação endoscópica foi realizada com CTS Relief Kit (Linvatec. Largo, FL, EUA) e um artroscópio padrão de 4 mm e 30°. Resultados O estudo incluiu 39 pacientes, sendo 29 (74,4%) homens e 10 (25,6%) mulheres. A idade dos pacientes variou de 12 a 64 anos (33 ± 14,97). Cinco pacientes foram submetidos à liberação bilateral. A liberação provocou melhora estatisticamente significativa de dor (p= 0,002), sensibilidade (p <0,001) e força (p <0,001). Os melhores resultados foram obtidos quando a liberação ulnar foi realizada em menos de 6 meses após a indicação da cirurgia. Nenhum procedimento foi convertido de endoscópico para aberto. Não foram relatadas complicações maiores (infecção, lesão vascular e lesão nervosa). Um paciente apresentou subluxação do nervo ulnar. Conclusão A liberação endoscópica do nervo ulnar no cotovelo na neurite hansênica traz benefícios verdadeiros e seguros para o paciente, como melhora da dor, sensibilidade e força.


Assuntos
Humanos , Neuropatias Ulnares , Síndrome do Túnel Ulnar/terapia , Endoscopia
4.
Rev Bras Ortop (Sao Paulo) ; 57(5): 863-867, 2022 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-36226223

RESUMO

Objectives The capsuloligamentous structures of the shoulder work as static stabilizers, together with the biceps and rotator cuff muscles, increasing the contact surface of the glenoid cavity. Free nerve endings and mechanoreceptors have been identified in the shoulder; however, there are a few studies that describe the presence of these nerves in the biceps' insertion. The present study aimed to describe the morphology and distribution of nerve endings using immunofluorescence with protein gene product 9.5 (PGP 9.5) and confocal microscopy. Methods Six labrum-biceps complexes from six fresh-frozen cadavers were studied. The specimens were coronally cut and prepared using the immunofluorescence technique. In both hematoxylin and eosin (H&E) and immunofluorescence, the organization of the connective tissue with parallel collagen fibers was described. Results In the H&E study, vascular structures and some nerve structures were visualized, which were identified by the elongated presence of the nerve cell. All specimens analyzed with immunofluorescence and confocal microscopy demonstrated poor occurrence of morphotypes of sensory corpuscles and free nerve endings. We identified free nerve endings located in the labrum and in the bicipital insertion, and sparse nerve endings along the tendon. Corpuscular endings with fusiform, cuneiform, and oval aspect were identified in the tendon. Conclusion These findings support the hypothesis that the generation of pain in the superior labral tear from Anterior to posterior (SLAP) lesions derives from the more proximal part of the long biceps cord and even more from the upper labrum. Future quantitative studies with a larger number of specimens may provide more information on these sensory systems.

5.
Rev. bras. ortop ; 57(5): 863-867, Sept.-Oct. 2022. graf
Artigo em Inglês | LILACS | ID: biblio-1407705

RESUMO

Abstract Objectives The capsuloligamentous structures of the shoulder work as static stabilizers, together with the biceps and rotator cuff muscles, increasing the contact surface of the glenoid cavity. Free nerve endings and mechanoreceptors have been identified in the shoulder; however, there are a few studies that describe the presence of these nerves in the biceps' insertion. The present study aimed to describe the morphology and distribution of nerve endings using immunofluorescence with protein gene product 9.5 (PGP 9.5) and confocal microscopy. Methods Six labrum-biceps complexes from six fresh-frozen cadavers were studied. The specimens were coronally cut and prepared using the immunofluorescence technique. In both hematoxylin and eosin (H&E) and immunofluorescence, the organization of the connective tissue with parallel collagen fibers was described. Results In the H&E study, vascular structures and some nerve structures were visualized, which were identified by the elongated presence of the nerve cell. All specimens analyzed with immunofluorescence and confocal microscopy demonstrated poor occurrence of morphotypes of sensory corpuscles and free nerve endings. We identified free nerve endings located in the labrum and in the bicipital insertion, and sparse nerve endings along the tendon. Corpuscular endings with fusiform, cuneiform, and oval aspect were identified in the tendon. Conclusion These findings support the hypothesis that the generation of pain in the superior labral tear from Anterior to posterior (SLAP) lesions derives from the more proximal part of the long biceps cord and even more from the upper labrum. Future quantitative studies with a larger number of specimens may provide more information on these sensory systems.


Resumo Objetivos As estruturas capsulo-ligamentares do ombro funcionam como estabilizadores estáticos, juntamente com os músculos do bíceps e do manguito rotador, aumentando a superfície de contato da cavidade glenoide. Terminações nervosas livres e mecanorreceptores foram identificados no ombro; no entanto, existem alguns estudos que descrevem a presença desses nervos na inserção do bíceps. Este estudo teve como objetivo descrever a morfologia e distribuição de terminações nervosas utilizando imunofluorescência com protein gene product 9.5 (PGP 9.5) e microscopia confocal. Métodos Foram estudados seis complexos labrum-bíceps de seis cadáveres congelados frescos. Os espécimes foram cortados coronalmente e preparados pelo método de imunofluorescência. Tanto em hematoxilina e eosina (H&E) quanto em imunofluorescência, foi descrita a organização do tecido conjuntivo com fibras paralelas de colágeno. Resultados No estudo de H&E, foram visualizadas estruturas vasculares e algumas estruturas nervosas, que foram identificadas pela presença alongada da célula nervosa. Todas as amostras analisadas com imunofluorescência e microscopia confocal demonstraram baixa ocorrência de morfotipos de corpúsculos sensoriais e terminações nervosas livres. Identificamos terminações nervosas livres localizadas no labrum, inserção bicipital e terminações nervosas esparsas ao longo do tendão. Terminais corpusculares com aspecto fusiforme, cuneiforme e oval foram identificados no tendão. Conclusão Esses achados corroboram a hipótese de que a geração de dor nas lesões labrais superiores de anterior a posterior (SLAP, na sigla em inglês) deriva da parte mais proximal do cabo longo do bíceps e ainda mais do labrum superior. Estudos quantitativos futuros com um número maior de espécimes podem fornecer mais informações sobre esses sistemas sensoriais.


Assuntos
Humanos , Articulação do Ombro , Cadáver , Imunofluorescência , Músculos Isquiossurais , Mecanorreceptores , Terminações Nervosas
6.
Acta Ortop Bras ; 29(5): 253-257, 2021.
Artigo em Inglês | MEDLINE | ID: mdl-34629949

RESUMO

OBJECTIVE: To quantify the neural elements in the posterior cruciate ligament (PCL) in healthy knees and with primary osteoarthrosis (OA). METHODS: In two groups with OA, one of cadavers and another of individuals, the area of neural elements identified in histological sections of PCL with anti-S100 immunohistochemistry was quantified. RESULTS: The overall mean area of the neural elements was 0.96% ± 0.67%, with the value in the cadaver group of 1.02% ± 0.67% and in the OA group of 0.80% ± 0.64%, with a significant statistically difference (p = 0.001). No correlation was observed between neural element quantification and the age of the individuals (p > 0.05). There was no difference in the quantification of neural elements between the sexes in the cadaver group (p = 0.766), but in the OA group there was a statistically significant reduction in males (p = 0.003). Also, in the osteoarthrosis group there was no difference in the quantification of neural elements in the knees with varus or valgus alignment (p = 0.847). CONCLUSION: There was a decrease in neural element quantification in PCL of individuals affected by OA in relation to non-arthritic individuals, with this quantification not related to age or with the axis of the lower limb. However, this quantification is not related to age or the axis of the lower limb. Level of Evidence III, Case control study.


OBJETIVO: Quantificar os elementos neurais no ligamento cruzado posterior (LCP) em joelhos hígidos e com osteoartrose primária (OA). MÉTODOS: Em um grupo de cadáveres e outro de indivíduos com ao, foi realizada a quantificação da área dos elementos neurais identificados em cortes histológicos do LCP com imunohistoquímica anti-S100. RESULTADOS: A média geral da área dos elementos neurais foi 0,96% ± 0,67%, com o valor no grupo cadáver de 1,02% ± 0,67% e no grupo OA de 0,80% ± 0,64%, havendo uma diferença estatisticamente significante (p = 0,001). Não se observou correlação entre a quantificação dos elementos neurais e a idade dos indivíduos (p > 0,05). Não se observou diferença na quantificação dos elementos neurais entre os sexos no grupo cadáver (p = 0,766), mas no grupo OA se observou redução estatisticamente significante no sexo masculino (p = 0,003). No grupo OA não houve diferença na quantificação dos elementos neurais nos joelhos com alinhamento varo ou valgo (p = 0,847). CONCLUSÃO: Foi demonstrada uma redução na quantificação dos elementos neurais no LCP de indivíduos acometidos por OA em relação aos indivíduos não artrósicos, com essa quantificação não tendo relação com idade nem com o eixo do membro inferior. Nível de evidência III, Estudo de caso controle.

7.
Acta ortop. bras ; 29(5): 253-257, Sept.-Oct. 2021. tab, graf
Artigo em Inglês | LILACS-Express | LILACS | ID: biblio-1339062

RESUMO

ABSTRACT Objective: To quantify the neural elements in the posterior cruciate ligament (PCL) in healthy knees and with primary osteoarthrosis (OA). Methods: In two groups with OA, one of cadavers and another of individuals, the area of neural elements identified in histological sections of PCL with anti-S100 immunohistochemistry was quantified. Results: The overall mean area of the neural elements was 0.96% ± 0.67%, with the value in the cadaver group of 1.02% ± 0.67% and in the OA group of 0.80% ± 0.64%, with a significant statistically difference (p = 0.001). No correlation was observed between neural element quantification and the age of the individuals (p > 0.05). There was no difference in the quantification of neural elements between the sexes in the cadaver group (p = 0.766), but in the OA group there was a statistically significant reduction in males (p = 0.003). Also, in the osteoarthrosis group there was no difference in the quantification of neural elements in the knees with varus or valgus alignment (p = 0.847). Conclusion: There was a decrease in neural element quantification in PCL of individuals affected by OA in relation to non-arthritic individuals, with this quantification not related to age or with the axis of the lower limb. However, this quantification is not related to age or the axis of the lower limb. Level of Evidence III, Case control study.


RESUMO Objetivo: Quantificar os elementos neurais no ligamento cruzado posterior (LCP) em joelhos hígidos e com osteoartrose primária (OA). Métodos: Em um grupo de cadáveres e outro de indivíduos com ao, foi realizada a quantificação da área dos elementos neurais identificados em cortes histológicos do LCP com imunohistoquímica anti-S100. Resultados: A média geral da área dos elementos neurais foi 0,96% ± 0,67%, com o valor no grupo cadáver de 1,02% ± 0,67% e no grupo OA de 0,80% ± 0,64%, havendo uma diferença estatisticamente significante (p = 0,001). Não se observou correlação entre a quantificação dos elementos neurais e a idade dos indivíduos (p > 0,05). Não se observou diferença na quantificação dos elementos neurais entre os sexos no grupo cadáver (p = 0,766), mas no grupo OA se observou redução estatisticamente significante no sexo masculino (p = 0,003). No grupo OA não houve diferença na quantificação dos elementos neurais nos joelhos com alinhamento varo ou valgo (p = 0,847). Conclusão: Foi demonstrada uma redução na quantificação dos elementos neurais no LCP de indivíduos acometidos por OA em relação aos indivíduos não artrósicos, com essa quantificação não tendo relação com idade nem com o eixo do membro inferior. Nível de evidência III, Estudo de caso controle.

8.
Acta Ortop Bras ; 28(2): 60-64, 2020.
Artigo em Inglês | MEDLINE | ID: mdl-32425665

RESUMO

OBJECTIVE: To implement one analysis method of the ankle bone contour that could make a more precise ankle arthrodesis. METHODS: Twenty tomographies were submitted to 3D reconstruction. Seven points of anatomic interest for ankle arthrodesis with the three screws technique were marked with a triplannar marker. The median of the position of markers was estimated, and the union of the seven median points allow the construction of one median ankle for that population. Using this median ankle, sizes and angles for the screws position were determined. RESULTS: Two median ankles were reconstructed, left and right. The position of the screw passage were determined considering the anatomical parameters. In the right ankle the lateral to medial screw should enter 4.56 cm and 0.79 above and posterior to lateral malleolus, with one inclination of 17.34° in relation to tibial longitudinal axis; and 0° in relation to tibial axial plane. The position for the other two screws is also described. CONCLUSION: Our article is the first to presents one precise guide for ankle arthrodesis based on a populational assessment. Level of evidence II, Diagnostic Studies.


OBJETIVO: Implementar método de análise do contorno e alinhamento ósseos no tornozelo de uma população normal, possibilitando uma artrodese tibiotársica mais precisa. MÉTODOS: Tomografias de vinte tornozelos foram submetidas à reconstrução 3D. Nesses exames, 7 pontos anatômicos de interesse para a técnica de fixação com 3 parafusos foram identificados e marcados com indicadores da posição triplanar. As médias das localizações de cada ponto foram calculadas. A união dessas médias permitiu a reconstrução de um tornozelo padrão daquela população. Nesses tornozelos médios estudou-se os comprimentos e ângulos para a passagem dos parafusos. RESULTADOS: Dois tornozelos, direito e esquerdo, foram reconstruídos. A posição para a passagem dos parafusos em relação a parâmetros anatômicos foi determinada. Para o tornozelo direito, a passagem do parafuso de lateral para medial deve ocorrer com o ponto de entrada 4,56 cm acima e 0,79 cm posterior à ponta do maléolo lateral, com inclinação de 17,34° em relação ao eixo longitudinal e 0° em relação ao eixo axial da tíbia. As posições dos outros dois parafusos também estão descritas. CONCLUSÃO: Esse é o primeiro trabalho que apresenta um guia preciso para realização da artrodese do tornozelo, baseado em um estudo populacional. Nível de evidência II, Estudos Diagnósticos.

9.
Acta ortop. bras ; 28(2): 60-64, Mar.-Apr. 2020. tab, graf
Artigo em Inglês | LILACS-Express | LILACS | ID: biblio-1098030

RESUMO

ABSTRACT Objective: To implement one analysis method of the ankle bone contour that could make a more precise ankle arthrodesis. Methods: Twenty tomographies were submitted to 3D reconstruction. Seven points of anatomic interest for ankle arthrodesis with the three screws technique were marked with a triplannar marker. The median of the position of markers was estimated, and the union of the seven median points allow the construction of one median ankle for that population. Using this median ankle, sizes and angles for the screws position were determined. Results: Two median ankles were reconstructed, left and right. The position of the screw passage were determined considering the anatomical parameters. In the right ankle the lateral to medial screw should enter 4.56 cm and 0.79 above and posterior to lateral malleolus, with one inclination of 17.34° in relation to tibial longitudinal axis; and 0° in relation to tibial axial plane. The position for the other two screws is also described. Conclusion: Our article is the first to presents one precise guide for ankle arthrodesis based on a populational assessment. Level of evidence II, Diagnostic Studies.


RESUMO Objetivo: Implementar método de análise do contorno e alinhamento ósseos no tornozelo de uma população normal, possibilitando uma artrodese tibiotársica mais precisa. Métodos: Tomografias de vinte tornozelos foram submetidas à reconstrução 3D. Nesses exames, 7 pontos anatômicos de interesse para a técnica de fixação com 3 parafusos foram identificados e marcados com indicadores da posição triplanar. As médias das localizações de cada ponto foram calculadas. A união dessas médias permitiu a reconstrução de um tornozelo padrão daquela população. Nesses tornozelos médios estudou-se os comprimentos e ângulos para a passagem dos parafusos. Resultados: Dois tornozelos, direito e esquerdo, foram reconstruídos. A posição para a passagem dos parafusos em relação a parâmetros anatômicos foi determinada. Para o tornozelo direito, a passagem do parafuso de lateral para medial deve ocorrer com o ponto de entrada 4,56 cm acima e 0,79 cm posterior à ponta do maléolo lateral, com inclinação de 17,34° em relação ao eixo longitudinal e 0° em relação ao eixo axial da tíbia. As posições dos outros dois parafusos também estão descritas. Conclusão: Esse é o primeiro trabalho que apresenta um guia preciso para realização da artrodese do tornozelo, baseado em um estudo populacional. Nível de evidência II, Estudos Diagnósticos.

10.
Rev Bras Ortop (Sao Paulo) ; 54(2): 171-177, 2019 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-31363263

RESUMO

Objective To evaluate the classification proposed by David Dejour to describe trochlear dysplasia of the knee through inter- and intraobserver reproducibility measurements. Methods Ten patients with trochlear dysplasia were studied. Three physicians, members of the Sociedade Brasileira de Cirurgia do Joelho (Brazilian Society of Knee Surgery), were invited to evaluate the images. Intra- and interobserver analyses were performed at one-week intervals. Reproducibility was evaluated in four scenarios: using only radiography; using radiography and tomography; using radiography and consulting the classification; and using radiography and tomography, consulting the classification. Results The intraobserver evaluation presented discordant results. In the interobserver analysis, the degree of agreement was low for the analyses that used only radiography and excellent for those in which both radiography and tomography were used. Conclusion The Dejour classification presented a low intra- and interobserver reproducibility when only the profile radiography was used. It was demonstrated that the use of the radiography alone for classification may generate lack of uniformity even among experienced observers. However, when radiography and tomography were combined, reproducibility improved.

11.
Rev. bras. cir. plást ; 34(2): 196-203, apr.-jun. 2019. ilus, tab
Artigo em Inglês, Português | LILACS | ID: biblio-1015966

RESUMO

Introdução: A mamoplastia redutora é ainda um procedimento que desafia o cirurgião plástico. O objetivo é demonstrar os resultados no tratamento de variados graus de hipertrofia e ptose mamária utilizando-se a técnica de Marcação Única, proposta por Pessoa, durante o treinamento de novos cirurgiões plásticos. Métodos: Coorte retrospectivo de 95 pacientes submetidas à mamoplastia redutora pela técnica de Pessoa. Incluídas pacientes com ptose, hipertrofia, gigantomastia e/ou assimetria das mamas. Os procedimentos foram realizados por residentes do primeiro, segundo e terceiro ano. Como fatores de exclusão foram usados: distúrbios psicológicos, obesidade mórbida e/ou pacientes com indicação de implante de prótese sem redução de pele e/ou aréola. Foram avaliados a idade, sexo, volume resultante, grau de satisfação, complicações e dificuldades dos residentes para realização do procedimento cirúrgico. Resultados: Todas as pacientes do sexo feminino, com idade entre 21 e 61 anos. 90,53% das pacientes declararam-se muito satisfeitas, 5,26% satisfeitas, 3,16% pouco satisfeitas e 1,05% insatisfeita. Como complicações, foram observadas necrose de complexo areolopapilar (1,05%), epidermólise (11,58%) e deiscência de sutura (9,47%). As dificuldades encontradas pelos residentes, dependendo da etapa do procedimento cirúrgico, variaram entre 11,1% e 55,6%. Conclusões: Verificou-se alto grau de satisfação tanto da parte das pacientes quanto dos residentes envolvidos. Os resultados encontrados confirmam a efetividade da técnica no treinamento de residentes.


Introduction: Reduction mastoplasty is still a challenging procedure for plastic surgeons. The Objective is to show the results of the treatment of different degrees of breast hypertrophy using Pessoa's single marking technique performed while training plastic surgeons. Methods: A retrospective cohort of 95 patients underwent reduction mastoplasty using Pessoa's technique. The cohort included patients with breast ptosis, hypertrophy, gigantomastia, and/ or breast asymmetry. The procedures were performed by first-, second-, and third-year residents. The exclusion criteria were psychological disorders, morbid obesity, and/or indication for prosthesis implantation without skin and/or areola reduction. The analyzed factors were age, sex, final size, patient's degree of satisfaction, complications, and difficulties experienced by the residents in performing the surgery. Results: All patients were women aged between 21 and 61 years. Of the patients, 90.53% reported being very satisfied; 5.26%, satisfied; 3.16%, poorly satisfied; and 1.05%, dissatisfied. The complications observed were necrosis of the nipple-areola complex (1.05%), epidermolysis (11.58%), and suture dehiscence (9.47%). The rate of difficulty experienced by the residents varied between 11.1% and 55.6%, depending on the step of the surgical procedure. Conclusions: A high degree of satisfaction was reported by both the patients and residents. The results confirm the effectiveness of the technique while training residents.


Assuntos
Humanos , Feminino , Adulto , Pessoa de Meia-Idade , Cirurgia Plástica/métodos , Mama/cirurgia , Avaliação de Resultados em Cuidados de Saúde/métodos , Mamoplastia/efeitos adversos , Mamoplastia/métodos , Procedimentos de Cirurgia Plástica/efeitos adversos , Contorno Corporal/efeitos adversos , Contorno Corporal/métodos , Satisfação do Paciente , Procedimentos de Cirurgia Plástica/métodos , Estética
12.
BMC Musculoskelet Disord ; 20(1): 142, 2019 Apr 04.
Artigo em Inglês | MEDLINE | ID: mdl-30947710

RESUMO

BACKGROUND: The number of studies and clinical interest in the anterolateral ligament of the knee (ALL) has grown in recent years. A meticulous and accurate ALL dissection is vital in anatomic and biomechanical studies, and a standardized technique is not yet established. As such, the aim of this study was to describe a step-by-step ALL dissection technique that could help authors consistently identify the ALL. METHODS: Twenty knees from frozen adult cadavers, with no preference for sex or age, were included in the study. All the cadavers were dissected using the same technique to determine the incidence of the ALL. RESULTS: A transverse incision is performed in the iliotibial band (ITB), around 10 cm proximal to the topography of the lateral epicondyle of the femur. Next, the ITB undergoes anterograde blunt dissection until its insertion at Gerdy's tubercle in the tibia. Maintaining biceps femoris insertion, a dissection is performed anteriorly to it, until the lateral collateral ligament (LCL) is found. Using the LCL, internal rotation and 30 to 60° flexion as references, the ALL can be located in the anterolateral topography of the knee, with its origin near the lateral epicondyle (proximal and posterior) and insertion between Gerdy's tubercle and the fibula (4.0 mm to 7.0 mm below the tibial plateau), expanding to the lateral meniscus (between the body and anterior horn), exhibiting a mean length of 4.0 ± 0.4 cm and mean width of 5.5 ± 0.8 mm. CONCLUSIONS: The present article describes an effective and reproducible ALL dissection technique that made it was possible to identify the ligament in 100% of the cases in the present study.


Assuntos
Dissecação/métodos , Articulação do Joelho/anatomia & histologia , Ligamentos Articulares/anatomia & histologia , Adulto , Cadáver , Humanos
13.
Rev. bras. ortop ; 54(2): 171-177, Mar.-Apr. 2019. tab, graf
Artigo em Inglês | LILACS | ID: biblio-1013707

RESUMO

Abstract Objective To evaluate the classification proposed by David Dejour to describe trochlear dysplasia of the knee through inter- and intraobserver reproducibility measurements. Methods Ten patients with trochlear dysplasia were studied. Three physicians, members of the Sociedade Brasileira de Cirurgia do Joelho (Brazilian Society of Knee Surgery), were invited to evaluate the images. Intra- and interobserver analyses were performed at one-week intervals. Reproducibility was evaluated in four scenarios: using only radiography; using radiography and tomography; using radiography and consulting the classification; and using radiography and tomography, consulting the classification. Results The intraobserver evaluation presented discordant results. In the interobserver analysis, the degree of agreement was low for the analyses that used only radiography and excellent for those in which both radiography and tomography were used. Conclusion The Dejour classification presented a low intra- and interobserver reproducibilitywhenonly the profile radiography was used. It was demonstrated that the use of the radiography alone for classificationmay generate lack of uniformity even among experienced observers. However, when radiography and tomography were combined, reproducibility improved.


Resumo Objetivo Avaliar, pela reprodutibilidade interobservador e intraobservador, a classificação proposta por David Dejour para descrever a displasia troclear do joelho. Métodos Foram estudados dez pacientes com diagnóstico de displasia troclear. Três médicos membros da Sociedade Brasileira de Cirurgia do Joelho foram convidados para avaliar as imagens. Análises intra- e interobservador foram feitas com intervalo de uma semana. A reprodutibilidade foi avaliada em quatro cenários: uso de radiografia; uso de radiografia e tomografia; uso de radiografia, consultando-se a classificação no momento; e uso de radiografia e tomografia, consultando-se a classificação no momento. Resultados A avaliação intraobservador apresentou resultados discordantes. Na análise interobservador, o grau de concordância foi baixo para as análises que usavam apenas a radiografia e excelente para aquelas que associavamradiografia e tomografia. Conclusão A classificação de Dejour apresentou uma baixa reprodutibilidade intra e interobservador quando usada somente a radiografia em perfil. Demonstrou-se que o uso apenas da radiografia para classificar pode gerar falta de uniformidade até mesmo entre observadores experientes. Contudo, quando radiografia e tomografia foram associadas, a reprodutibilidade melhorou.


Assuntos
Humanos , Masculino , Feminino , Reprodutibilidade dos Testes , Articulação Patelofemoral , Instabilidade Articular
14.
Acta ortop. bras ; 26(6): 397-400, Nov.-Dec. 2018. graf
Artigo em Inglês | LILACS | ID: biblio-973584

RESUMO

ABSTRACT Objectives: To compare the accuracy of insertion of pedicle screws into the thoracic spine using fluoroscopic guidance or computer-assisted navigation techniques. Methods: Eight cadaveric thoracic spines were divided into two groups: the fluoroscopy group, in which pedicle screws were inserted with the guidance of a C-arm device, and the navigation group, in which insertion of the screws was monitored using computer-assisted navigation equipment. All procedures were performed by the same spinal surgeon. The rate of pedicle breach was compared between the two groups. Results: There was one intra-canal perforation in each group. Both perforations were medial in direction, and the breaches were 2 to 4 mm deep. There were no statistically significant differences in breach rate between the two groups. Conclusions: The accuracy of insertion of pedicle screws in the thoracic spine using computer-assisted navigation is equivalent to that achieved using fluoroscopic guidance. Computer-assisted navigation improves the safety of the surgical team during the procedure due to the absence of exposure to radiation. Therefore, there is a need for future randomized controlled trials to be conducted in the clinical setting to evaluate other outcomes, including duration of surgery and blood loss during the procedure. Level of evidence IV.


RESUMO Objetivos: Comparar a acurácia da inserção de parafusos pediculares na coluna torácica, utilizando fluoroscopia ou técnicas de navegação assistidas por computador. Métodos: Estudo experimental com cadáveres. Oito colunas torácicas proveniente de cadáveres foram divididas em dois grupos: no grupo Fluoroscopia os parafusos pediculares foram inseridos com orientação de um aparelho tipo C-arm, e no grupo Navegação o monitoramento foi feito com um equipamento de assistência por computador. Todos os procedimentos foram feitos pelo mesmo cirurgião de coluna. A taxa de violação do canal foi comparada entre os grupos. Resultados: Houve uma perfuração de canal em cada grupo, ambas mediais, com 2-4 mm de profundidade. Não houve diferenças significativas entre os dois grupos em termos de taxa de perfuração do canal. Conclusão: A acurácia na inserção de parafusos pediculares na coluna torácica é igual comparando-se a navegação assistida por computador e o método de monitoramento por fluoroscopia. Como a segurança do procedimento para a equipe cirúrgica é maior com o método da navegação, devido à ausência de exposição à radiação, há necessidade de se realizarem estudos clínicos controlados no ambiente clínico, que avaliem outros desfechos, como o tempo de cirurgia e de sangramento. Nível de evidência IV.

15.
Rev. bras. ortop ; 53(6): 661-667, Nov.-Dec. 2018. tab, graf
Artigo em Inglês | LILACS | ID: biblio-977902

RESUMO

ABSTRACT Recently described in the medical literature, the anterolateral ligament of the knee is already considered an important stabilizer against the anterolateral tibial rotation, affecting the pivot shift in the failure of the anterior cruciate ligament and behaving as an important secondary rotational stabilizer. The mechanism of anterolateral ligament injury combined with anterior cruciate ligament injury is similar to the mechanism of anterior cruciate ligament injury alone. Thus, the main objective of the joint reconstruction of anterior cruciate ligament and anterolateral ligament would be increased rotational control and prevention of anterior cruciate ligament re-rupture. In view of this importance, the aim of the present study is to summarize the evidence on the main surgical indications described for anterior cruciate ligament reconstruction combined with lateral extra-articular tenodesis or anterolateral ligament reconstruction. A review of the literature was conducted in April 2017, through a search of the PubMed, MEDLINE, Cochrane, and Google Scholar databases, with no date limits. After reviewing the main articles in the subject, it was concluded that the main surgical indications described for anterior cruciate reconstruction combined with extra-articular lateral tenodesis or anterolateral ligament reconstruction are: anterior cruciate ligament revision, physical examination with pivotal shift grade 2 or 3, practice of sport with pivot mechanism and/or high level mechanism, ligament laxity and Segond fracture; Secondly, the following may also be indications: chronic anterior cruciate ligament injury, age less than 25 years old, and radiological sign of lateral femoral condyle depression. However, it is worth mentioning that more studies are still needed to prove these trends.


RESUMO Recentemente descrito na literatura médica, o ligamento anterolateral do joelho já é considerado um importante estabilizador contra a rotação tibial anterolateral, afeta o pivot shift na falha do ligamento cruzado anterior e comporta-se como um grande estabilizador secundário rotacional. O mecanismo de lesão do ligamento anterolateral combinado com a lesão do ligamento cruzado anterior é semelhante ao mecanismo da lesão isolada do ligamento cruzado anterior. Assim, o principal objetivo da reconstrução conjunta do ligamento cruzado anterior e do ligamento anterolateral seria um maior controle rotacional e prevenção da rerruptura do ligamento cruzado anterior. Tendo em vista tal importância, o objetivo do presente trabalho é resumir as evidências sobre as principais indicações cirúrgicas descritas para reconstrução do ligamento cruzado anterior combinada com tenodese extra-articular lateral ou reconstrução do ligamento anterolateral. Foi feita uma revisão da literatura em abril de 2017, por meio de pesquisa nas bases de dados PubMed, Medline, Cochrane e Google Scholar, sem limites de data. Após revisão dos principais artigos no assunto, os autores concluíram que as principais indicações cirúrgicas descritas para reconstrução do ligamento cruzado anterior combinada com tenodese extra-articular lateral ou reconstrução do ligamento anterolateral são: revisão do ligamento cruzado anterior, exame físico com pivot shift grau 2 ou 3, prática de esporte com mecanismo de pivot e/ou de alto nível, frouxidão ligamentar e fratura de Segond. Secundariamente, as seguintes indicações são possíveis: lesão crônica de ligamento cruzado anterior, idade menor de que 25 anos e sinal radiológico de afundamento do côndilo femoral lateral. Todavia, vale ressaltar que mais estudos ainda são necessários para comprovar essas tendências.


Assuntos
Reconstrução do Ligamento Cruzado Anterior , Instabilidade Articular , Joelho
16.
Rev Bras Ortop ; 53(6): 661-667, 2018.
Artigo em Inglês | MEDLINE | ID: mdl-30377597

RESUMO

Recently described in the medical literature, the anterolateral ligament of the knee is already considered an important stabilizer against the anterolateral tibial rotation, affecting the pivot shift in the failure of the anterior cruciate ligament and behaving as an important secondary rotational stabilizer. The mechanism of anterolateral ligament injury combined with anterior cruciate ligament injury is similar to the mechanism of anterior cruciate ligament injury alone. Thus, the main objective of the joint reconstruction of anterior cruciate ligament and anterolateral ligament would be increased rotational control and prevention of anterior cruciate ligament re-rupture. In view of this importance, the aim of the present study is to summarize the evidence on the main surgical indications described for anterior cruciate ligament reconstruction combined with lateral extra-articular tenodesis or anterolateral ligament reconstruction. A review of the literature was conducted in April 2017, through a search of the PubMed, MEDLINE, Cochrane, and Google Scholar databases, with no date limits. After reviewing the main articles in the subject, it was concluded that the main surgical indications described for anterior cruciate reconstruction combined with extra-articular lateral tenodesis or anterolateral ligament reconstruction are: anterior cruciate ligament revision, physical examination with pivotal shift grade 2 or 3, practice of sport with pivot mechanism and/or high level mechanism, ligament laxity and Segond fracture; Secondly, the following may also be indications: chronic anterior cruciate ligament injury, age less than 25 years old, and radiological sign of lateral femoral condyle depression. However, it is worth mentioning that more studies are still needed to prove these trends.


Recentemente descrito na literatura médica, o ligamento anterolateral do joelho já é considerado um importante estabilizador contra a rotação tibial anterolateral, afeta o pivot shift na falha do ligamento cruzado anterior e comporta-se como um grande estabilizador secundário rotacional. O mecanismo de lesão do ligamento anterolateral combinado com a lesão do ligamento cruzado anterior é semelhante ao mecanismo da lesão isolada do ligamento cruzado anterior. Assim, o principal objetivo da reconstrução conjunta do ligamento cruzado anterior e do ligamento anterolateral seria um maior controle rotacional e prevenção da rerruptura do ligamento cruzado anterior. Tendo em vista tal importância, o objetivo do presente trabalho é resumir as evidências sobre as principais indicações cirúrgicas descritas para reconstrução do ligamento cruzado anterior combinada com tenodese extra-articular lateral ou reconstrução do ligamento anterolateral. Foi feita uma revisão da literatura em abril de 2017, por meio de pesquisa nas bases de dados PubMed, Medline, Cochrane e Google Scholar, sem limites de data. Após revisão dos principais artigos no assunto, os autores concluíram que as principais indicações cirúrgicas descritas para reconstrução do ligamento cruzado anterior combinada com tenodese extra-articular lateral ou reconstrução do ligamento anterolateral são: revisão do ligamento cruzado anterior, exame físico com pivot shift grau 2 ou 3, prática de esporte com mecanismo de pivot e/ou de alto nível, frouxidão ligamentar e fratura de Segond. Secundariamente, as seguintes indicações são possíveis: lesão crônica de ligamento cruzado anterior, idade menor de que 25 anos e sinal radiológico de afundamento do côndilo femoral lateral. Todavia, vale ressaltar que mais estudos ainda são necessários para comprovar essas tendências.

17.
Rev Bras Ortop ; 53(6): 792-796, 2018.
Artigo em Inglês | MEDLINE | ID: mdl-30377618

RESUMO

For decades, the main cause of failure in total knee arthroplasty (TKA) is still the malalignment of prosthetic components. The authors present a case of advanced knee arthrosis, treated by TKA. Preoperative planning was performed with a mobile application and the patient was submitted to primary TKA using an implant developed with inspiration from the theory of "modified GAP" with a rotated tibial tray. Neutral mechanical alignment of the lower limbs was obtained and the application proved to be viable regarding its proposed plan for this case.


Ao longo das décadas, a principal causa de insucesso em artroplastias totais do joelho (ATJ) continua a ser o mau alinhamento dos componentes protéticos. Os autores apresentam um caso de artrose avançada do joelho tratado por ATJ. O planejamento pré-operatório foi feito a partir de um aplicativo para dispositivos móveis e a paciente foi submetida à ATJ primária, com um implante desenvolvido com inspiração na teoria do "GAP modificado", com base tibial rotatória. O alinhamento mecânico neutro dos membros inferiores foi obtido e o aplicativo mostrou-se viável em sua proposta de planejamento para este caso.

18.
Rev Col Bras Cir ; 45(1): e1577, 2018.
Artigo em Português, Inglês | MEDLINE | ID: mdl-29451647

RESUMO

OBJECTIVES: to evaluate estradiol levels and autotransplantation heated ovarian tissue effects, after vitrification, on rats bone metabolism previously oophorectomized bilaterally. METHODS: experimental study with 27 rats aged 11 to 12 weeks and weighing 200g to 300g, submitted to bilateral oophorectomy and ovarian tissue cryopreservation for subsequent reimplantation. Animals were divided into two groups, A and B, with 8 and 19 rats, respectively. Autotransplantation occurred in two periods according to castration time: after one week, in group A, and after one month in group B. Serum estradiol measurements and ovary and tibia histological analysis were performed before and after oophorectomy period (early or late) and one month after reimplantation. RESULTS: in groups A and B, tibia median cortical thickness was 0.463±0.14mm (mean±SD) at the baseline, 0.360±0.14mm after oophorectomy and 0.445±0.17mm one month after reimplantation p<0.005). Trabecular means were 0.050±0.08mm (mean±SD) at baseline, 0.022±0.08mm after oophorectomy and 0.049±0.032mm one month after replantation (p<0.005). There was no statistical difference in estradiol variation between the two study groups (p=0.819). CONCLUSION: cryopreserved ovarian tissue transplantation restored bone parameters, and these results suggest that ovarian reimplantation in women may have the same beneficial effects on bone metabolism.


Assuntos
Osso e Ossos/metabolismo , Criopreservação , Ovário/transplante , Animais , Estradiol/sangue , Feminino , Ovariectomia , Ratos , Ratos Wistar
19.
Rev. Col. Bras. Cir ; 45(1): e1577, fev. 2018. graf
Artigo em Inglês | LILACS | ID: biblio-956549

RESUMO

ABSTRACT Objectives: to evaluate estradiol levels and autotransplantation heated ovarian tissue effects, after vitrification, on rats bone metabolism previously oophorectomized bilaterally. Methods: experimental study with 27 rats aged 11 to 12 weeks and weighing 200g to 300g, submitted to bilateral oophorectomy and ovarian tissue cryopreservation for subsequent reimplantation. Animals were divided into two groups, A and B, with 8 and 19 rats, respectively. Autotransplantation occurred in two periods according to castration time: after one week, in group A, and after one month in group B. Serum estradiol measurements and ovary and tibia histological analysis were performed before and after oophorectomy period (early or late) and one month after reimplantation. Results: in groups A and B, tibia median cortical thickness was 0.463±0.14mm (mean±SD) at the baseline, 0.360±0.14mm after oophorectomy and 0.445±0.17mm one month after reimplantation p<0.005). Trabecular means were 0.050±0.08mm (mean±SD) at baseline, 0.022±0.08mm after oophorectomy and 0.049±0.032mm one month after replantation (p<0.005). There was no statistical difference in estradiol variation between the two study groups (p=0.819). Conclusion: cryopreserved ovarian tissue transplantation restored bone parameters, and these results suggest that ovarian reimplantation in women may have the same beneficial effects on bone metabolism.


RESUMO Objetivos: avaliar os níveis de estradiol e os efeitos do autotransplante de tecido ovariano aquecido, após vitrificação, no metabolismo ósseo de ratas previamente ooforectomizadas bilateralmente. Métodos: trabalho experimental com 27 ratas com idades entre 11 e 12 semanas e pesando 200g a 300g, submetidas à ooforectomia bilateral e criopreservação de tecido ovariano para posterior reimplante. Os animais foram divididos em dois grupos, A e B, com oito e 19 ratas, respectivamente. O autotransplante ocorreu em dois períodos de acordo com o tempo de castração: após uma semana, no grupo A, e após um mês no grupo B. Mensurações de estradiol sérico e análise histológica de ovário e tíbia foram feitos antes e após o período de ooforectomia (precoce ou tardio) e um mês após o reimplante. Resultados: nos grupos A e B, as espessuras corticais médias da tíbia foram 0,463±0,14mm (média±DP) na linha de base, 0,360±0,14mm após ooforectomia e 0,445±0,17mm em um mês após o reimplante (p<0,005). As médias trabeculares foram 0,050±0,08mm (média±DP) na linha de base, 0,022±0,08mm após ooforectomia e 0,049±0,032mm em um mês após o reimplante (p<0,005). Não houve diferença estatística entre a variação do estradiol entre os dois grupos de estudo (p=0,819). Conclusão: o transplante de tecido ovariano criopreservado restabeleceu os parâmetros ósseos, e estes resultados sugerem que a reimplantação ovariana em mulheres pode apresentar os mesmos efeitos benéficos sobre o metabolismo ósseo.


Assuntos
Animais , Feminino , Ratos , Ovário/transplante , Osso e Ossos/metabolismo , Criopreservação , Ovariectomia , Ratos Wistar , Estradiol/sangue
20.
Acta Ortop Bras ; 26(6): 397-400, 2018.
Artigo em Inglês | MEDLINE | ID: mdl-30774514

RESUMO

OBJECTIVES: To compare the accuracy of insertion of pedicle screws into the thoracic spine using fluoroscopic guidance or computer-assisted navigation techniques. METHODS: Eight cadaveric thoracic spines were divided into two groups: the fluoroscopy group, in which pedicle screws were inserted with the guidance of a C-arm device, and the navigation group, in which insertion of the screws was monitored using computer-assisted navigation equipment. All procedures were performed by the same spinal surgeon. The rate of pedicle breach was compared between the two groups. RESULTS: There was one intra-canal perforation in each group. Both perforations were medial in direction, and the breaches were 2 to 4 mm deep. There were no statistically significant differences in breach rate between the two groups. CONCLUSIONS: The accuracy of insertion of pedicle screws in the thoracic spine using computer-assisted navigation is equivalent to that achieved using fluoroscopic guidance. Computer-assisted navigation improves the safety of the surgical team during the procedure due to the absence of exposure to radiation. Therefore, there is a need for future randomized controlled trials to be conducted in the clinical setting to evaluate other outcomes, including duration of surgery and blood loss during the procedure. Level of evidence IV.


OBJETIVOS: Comparar a acurácia da inserção de parafusos pediculares na coluna torácica, utilizando fluoroscopia ou técnicas de navegação assistidas por computador. MÉTODOS: Estudo experimental com cadáveres. Oito colunas torácicas proveniente de cadáveres foram divididas em dois grupos: no grupo Fluoroscopia os parafusos pediculares foram inseridos com orientação de um aparelho tipo C-arm, e no grupo Navegação o monitoramento foi feito com um equipamento de assistência por computador. Todos os procedimentos foram feitos pelo mesmo cirurgião de coluna. A taxa de violação do canal foi comparada entre os grupos. RESULTADOS: Houve uma perfuração de canal em cada grupo, ambas mediais, com 2-4 mm de profundidade. Não houve diferenças significativas entre os dois grupos em termos de taxa de perfuração do canal. CONCLUSÃO: A acurácia na inserção de parafusos pediculares na coluna torácica é igual comparando-se a navegação assistida por computador e o método de monitoramento por fluoroscopia. Como a segurança do procedimento para a equipe cirúrgica é maior com o método da navegação, devido à ausência de exposição à radiação, há necessidade de se realizarem estudos clínicos controlados no ambiente clínico, que avaliem outros desfechos, como o tempo de cirurgia e de sangramento. Nível de evidência IV.

SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...